Initial Setting Time of Cement
- Get link
- X
- Other Apps
Image Source:-civilread.com |
It is the time when water is added to cement and the time at which needle of 1mm2 section fails to penetrate the depth block to a depth of 5 to 7 mm from the bottom of mould.
Important Terms:-
(i) Take 0.85P of water. (Where, P is normal consistency)
(ii) 1mm2 needle is used.
(iii) Penetration should be 5 to 7 mm from bottom.
(iv) Mixing, placing and testing should be done between 3 to 5 mm.
Recent Post:- Aggregate Impact Value Test
Test Procedure:-
Image Source:civilblog.org |
(i) 400 gm of cement sample is taken.
(ii) 0.85 P=(0.85 P X 26/100) X 400
= 88.4 CC (CC-Cubic Centimeter)
(1 cc=1 ml)
Image Source:aust.edu |
Also Read: Consistency Cement of Test
(iii) 88.4 ml water is mixed and filled in the mould.
(iv) 1mm2 diameter of plunger is fixed and at bottom of vicat apparatus, mould will placed and needle will just touch and freely filled. Now reading=0
(v) After interval of sometimes we will proceed for penetration. Till reading not comes in the range of 5 mm to 7 mm. Again penetration is applied and now reading is=7 mm.
Note:-
Image Source:-civilread.com |
Also Read: Elongation Test of an Aggregate
After many times penetration and free fall when results will not comes under 5 mm to 7 mm, we have repeted this procedure.
Mould placing timing=8:25 A.M.
Testing Completed timing=9:00 A.M.
So, initial setting time=35 minutes